ARA-290 (16mg)
Tissue Repair Without Blood Cell Effects
Order ARA-290 (16mg) online for laboratory research. Compare the listed vial options and current price, then add your selection to cart and continue to checkout. Review available COA records for the exact product, strength and lot. Research Use Only; not for human or veterinary use.
ARA-290 is listed for specialty laboratory research. Catalog vial contents are 16mg; select the required strength before ordering. This material is supplied for Research Use Only, not as a medicine or a product for human or veterinary use.
Research Applications & Benefits
- Tissue protection without blood effects
- Activates innate repair receptor
- Neuroprotective
What is ARA-290?
Derived from EPO but activates ONLY the tissue-protective pathway.
Listed vial contents: 16mg. These are supplied quantities, not administration doses. Current pricing and availability are shown in the strength selector.
What mechanisms are being studied?
ARA-290 is an 11-amino acid peptide derived from erythropoietin (EPO) that selectively activates the innate repair receptor (IRR). Unlike EPO, it does NOT stimulate erythropoiesis or increase hematocrit. It provides tissue-protective and anti-inflammatory effects through an entirely separate signaling pathway.
What are the research questions?
- Sarcoidosis (small fiber neuropathy): Phase 2 trials showed improvement in neuropathic pain and small fiber density.
- Diabetic neuropathy: Studied for nerve repair and pain reduction in diabetic small fiber neuropathy.
- Tissue repair: Activates the innate repair receptor for tissue protection without hematological effects.
- Chronic pain: Anti-inflammatory and neuroprotective mechanisms address chronic pain pathways.
What does the published work describe?
Brines M et al. — Phase 2 trials showed improvement in corneal nerve fiber density and reduction in neuropathic pain scores in sarcoidosis patients. No hematological effects confirmed.
What are the limits of this evidence?
The research described concerns the cited experimental materials and models, not proof that this supplied vial is a treatment. Cell or animal findings do not establish human benefits. Clinical findings, where cited, apply to the tested formulation and population; they do not validate this research product for human use.
Study references
- Brines M et al. Mol Med 2008
These are the catalog's existing bibliographic references. No new source verification is implied by this presentation.
How should I check lot documentation?
Match the product, strength and lot to an original analysis document. Literature describes experimental findings; it does not verify the contents of this inventory. A report is evidence only for the product, strength and lot it names.
How is ARA-290 handled in the lab?
For ARA-290, record the product code ARA, selected strength and lot before opening. Follow the material-specific safety data sheet and laboratory SOP, with appropriate gloves, eye protection and containment. For a documented dry preparation, let the sealed vial equilibrate before opening to reduce condensation; minimize time open and use clean, compatible vessels.
Choose a solvent for ARA-290 from the documented sequence or chemical identity, salt form and assay requirements. Test a small portion first and record pH, solvent composition and clarity. Do not assume one diluent works for every research material; include a solvent-only control and establish compatibility before using the stock in an assay.
For ARA-290, calculate mass concentration as measured material mass divided by final solution volume. Calculate molarity only with a documented molecular weight for the supplied chemical form; no usable molecular weight is established by the blank catalog field. Where available, use matched-lot net content rather than treating chromatographic purity as a mass correction. Record both stock concentration and subsequent dilution factors.
Use the documented storage conditions for the supplied ARA-290 form and lot. For a documented lyophilized preparation, keep the vial sealed and protected from moisture; for solutions, validate temperature, light exposure and holding time in the assay. Use compatible single-use aliquots when appropriate to reduce repeated freeze-thaw. No universal temperature or 28-day solution shelf life is established by the catalog name.
A ARA-290 laboratory protocol should record identity, product code ARA, strength, lot, applicable analysis results, solvent and pH, stock concentration, dilution sequence, vessel type, storage history and assay endpoints. Include vehicle and reference controls, independent replicates and predefined acceptance criteria. Separate handling validation from biological interpretation; these notes do not provide administration or dosing instructions.
Research Use Only. Not for human consumption, therapeutic, veterinary or any in-vivo use.
Product Specifications
- Compound
- ARA-290
- CAS Number
- Molecular Weight
- HPLC Purity Specification
- ≥98%
- Category
- Specialty
- Starting Price
- $89.00 USD
- Country of Origin
- United States
- Shipping
- Cold-chain insulated packaging, fast domestic delivery
- Payment
- Card, ACH, and cryptocurrency (10% discount)
Quality & Verification
ARA-290 has a catalog purity specification of ≥98%; this is not a measured result for every vial. Match the product, exact strength, batch and lot to its analysis record and read only the reported fields. HPLC peak-area purity, measured content and endotoxin are separate measurements. A blank field means no result is reported, not zero or passed. A purity percentage alone does not establish identity, sterility or suitability for human use.
Frequently Asked Questions
What is ARA-290?
ARA-290 is listed for specialty laboratory research. Catalog vial contents are 16mg; select the required strength before ordering. This material is supplied for Research Use Only, not as a medicine or a product for human or veterinary use.
What strengths of ARA-290 are available?
The catalog lists 16mg. These labels describe vial contents, not administration doses. Select the required strength for current pricing and availability; match analysis records to that exact strength and lot.
How should I interpret ARA-290 purity results?
ARA-290 has a catalog purity specification of ≥98%; this is not a measured result for every vial. Match the product, exact strength, batch and lot to its analysis record and read only the reported fields. HPLC peak-area purity, measured content and endotoxin are separate measurements. A blank field means no result is reported, not zero or passed. A purity percentage alone does not establish identity, sterility or suitability for human use.
How should ARA-290 be handled in the laboratory?
For ARA-290, record the product code ARA, selected strength and lot before opening. Follow the material-specific safety data sheet and laboratory SOP, with appropriate gloves, eye protection and containment. For a documented dry preparation, let the sealed vial equilibrate before opening to reduce condensation; minimize time open and use clean, compatible vessels.
How do I choose a laboratory solvent for ARA-290?
Choose a solvent for ARA-290 from the documented sequence or chemical identity, salt form and assay requirements. Test a small portion first and record pH, solvent composition and clarity. Do not assume one diluent works for every research material; include a solvent-only control and establish compatibility before using the stock in an assay.
How do I calculate a ARA-290 stock concentration?
For ARA-290, calculate mass concentration as measured material mass divided by final solution volume. Calculate molarity only with a documented molecular weight for the supplied chemical form; no usable molecular weight is established by the blank catalog field. Where available, use matched-lot net content rather than treating chromatographic purity as a mass correction. Record both stock concentration and subsequent dilution factors.
How should ARA-290 be stored after preparation?
Use the documented storage conditions for the supplied ARA-290 form and lot. For a documented lyophilized preparation, keep the vial sealed and protected from moisture; for solutions, validate temperature, light exposure and holding time in the assay. Use compatible single-use aliquots when appropriate to reduce repeated freeze-thaw. No universal temperature or 28-day solution shelf life is established by the catalog name.
What should a ARA-290 lab protocol document?
A ARA-290 laboratory protocol should record identity, product code ARA, strength, lot, applicable analysis results, solvent and pH, stock concentration, dilution sequence, vessel type, storage history and assay endpoints. Include vehicle and reference controls, independent replicates and predefined acceptance criteria. Separate handling validation from biological interpretation; these notes do not provide administration or dosing instructions.
Does Fmoc or Boc synthesis explain this ARA-290 product?
Fmoc and Boc are peptide protecting-group strategies, not proof of how this ARA-290 lot was made. For sequence-defined peptides, synthesis review can examine deletion products, incomplete deprotection and modifications using the method and matching analytical evidence. A single chromatographic peak does not by itself establish sequence.
Is ARA-290 for human use?
No. ARA-290 is strictly Research Use Only. It is not intended for human or veterinary use, diagnosis or treatment. Laboratory handling guidance is not an administration protocol.
Research Use Only. This product is intended for licensed laboratory research and is not for human or veterinary use.